來源:昌昇自動化時間:2021-06-18
安川變頻器主(zhu)回(hui)路(lu)欠(qian)電(dian)壓(ya)如(ru)何(he)維(wei)修(xiu)?欠(qian)電(dian)壓(ya)故(gu)障(zhang)也(ye)是(shi)變(bian)頻(pin)器(qi)使(shi)用(yong)中(zhong)經(jing)常(chang)碰(peng)到(dao)的(de)故(gu)障(zhang),電(dian)源(yuan)電(dian)壓(ya)降(jiang)低(di)後(hou),主(zhu)電(dian)路(lu)直(zhi)流(liu)電(dian)壓(ya)若(ruo)降(jiang)到(dao)欠(qian)電(dian)壓(ya)檢(jian)測(ce)值(zhi)以(yi)下(xia),欠(qian)電(dian)壓(ya)保(bao)護(hu)將(jiang)動(dong)作(zuo)。另(ling)外(wai),電(dian)壓(ya)若(ruo)降(jiang)到(dao)不(bu)能(neng)維(wei)持(chi)變(bian)頻(pin)器(qi)控(kong)製(zhi)電(dian)路(lu)工(gong)作(zuo),則(ze)全(quan)部(bu)保(bao)護(hu)功(gong)能(neng)自(zi)動(dong)複(fu)位(wei)(檢測值:DC 400V)。
dangchuxianqiandianyaguzhangshi,shouxianyinggaijianzhashurudianyuanshifouquexiang,jiarushurudianyuanmeiyouwenti,jiuyaojianzhazhengliuhuilushifouyouwenti,jiarudoumeiyouwenti,zaijianzhazhiliujiancedianlushifouyouwenti。ruguozhuhuiludianyataidi,zhuyaoyuanyinshizhengliumokuaimouyilusunhuaihuojingzhaguansanxiangdianluzhongyouyixianggongzuobuzhengchang,doukedaozhiqiandianyaguzhangdechuxian。qici,zhuhuiluduanluqi、接觸器損壞,也會導致直流母線電壓損耗在充電電阻上麵而導致欠電壓故障。
對於380V係列的變頻器,直流母線電壓下限為400V,即當直流母線電壓降至DC 400V以下時,變頻器才報直流母線低電壓故障。當兩相輸入時,直流母線電壓為380×1.2=452V> 400V。當變頻器不運行時,由於平波電容的作用,直流電壓也可達到正常值。新型的變頻器都是采用PWM控製技術,調壓調頻的工作由逆變橋完成,所以在低頻段輸入缺相仍可以正常工作,但將造成異步電動機轉矩低,頻率上不去。
安川變頻器UV-欠電壓故障檢修實例
故障現象:安川變頻器UV-欠壓故障。
故障分析與處理:
上一篇:enc變頻器報警9怎麼修 下一篇:倫茨變頻器接地故障維修分析